Vibration Analysis for Non-Experts: How to Read ISO 20816 and What Your Motors Are Telling You
First, a Correction Almost Nobody Has Made
If the vibration report that landed on your desk this week cites "according to ISO 10816-3," your contractor is referencing a withdrawn standard.
ISO 10816-3:2009 is officially listed as Withdrawn in the ISO catalog. It was replaced by ISO 20816-3:2022, published in October 2022, which also absorbed ISO 7919-3 (shaft vibration measurement). The new standard unifies in a single document the measurement on non-rotating parts—such as casings and bearing housings—as well as on the shaft itself. It also broadened the speed range covered: while the old standard capped at 15,000 r/min, the current one covers from 120 to 30,000 r/min for machines over 15 kW.
This isn't just a piece of regulatory trivia. It is a direct indicator of how up to date the person measuring your equipment actually is.
What ISO 20816 Tells You — and What It Doesn't
Here is the most expensive misunderstanding on the topic: ISO 20816 tells you how severe the condition is, not what is wrong with the machine.
The standard evaluates the overall vibration severity, typically expressed as RMS velocity in mm/s, measured on non-rotating parts across the 10 Hz to 1,000 Hz frequency band (2 Hz to 1,000 Hz for machines running below 600 rpm). It functions as a traffic light. It tells you whether you can keep operating, whether you should schedule a maintenance outage, or whether you are about to break something.
The actual diagnosis—unbalance, misalignment, bearing defects, or electrical problems—does not come from that overall number. It comes from the FFT spectrum, which is an entirely different tool and forms the second half of this article.
Many managers believe that "complying with ISO 20816" is the entirety of vibration analysis. Complying with the standard is merely the starting line.
How Your Machine Is Classified Before Being Judged
The standard does not apply the same threshold across all equipment. First, you must position the asset along two axes:
By Size:
Group 1: Large machines rated over 300 kW, or electrical machines with shaft height H ≥ 315 mm.
Group 2: Medium-sized machines, between 15 kW and 300 kW, or electrical machines with 160 mm ≤ H < 315 mm.
By Support Type:
Rigid: The first natural frequency of the machine-foundation system is above the rotational frequency. Typical of machines bolted down to a massive concrete base.
Flexible: The first natural frequency is below the rotational frequency. Typical of equipment mounted on vibration isolators, structural steel frames, or elevated floors.
The exact same 100 kW motor has a different allowable limit depending on whether it is anchored to the floor or mounted on an elevated platform. If your report doesn't specify the group or support type, it isn't applying the standard—it's applying a generic table someone pulled off the internet.
The Four Zones: The Real Traffic Light System
Zone | What It Means | What the Manager Should Do |
A | Vibration typical of newly commissioned machinery | Nothing. Record as baseline |
B | Acceptable for unrestricted long-term continuous operation | Operate normally; continue tracking trends |
C | Unsuitable for long-term continuous operation. May run for a limited period | Schedule maintenance. This is where you decide, not the machine |
D | Severity sufficient to cause damage to the machine | Catastrophic failure risk. Immediate intervention required |
The exact numerical boundary limits for A/B, B/C, and C/D vary by group and support type, and are detailed in the text of the standard—which is a paid document. A practical warning: contradictory and erroneous tables attributed to ISO 20816-3 circulate online, including on seemingly technical websites. If your decision to shut down a production line rests on a number, that number must come directly from the official standard or an accredited lab that owns it, not from a blog post.
And now for the golden rule you can apply without purchasing anything: the change matters more than the absolute value. A machine whose vibration jumped from 1.8 to 3.6 mm/s in two months has a developing problem, even if both readings fall safely within Zone B. The standard sets generic thresholds for a broad population of machines; the best baseline reference for your motor is its own historical data.
Do you have a vibration baseline for your critical equipment, or just isolated readings?
We can install continuous monitoring on a critical asset for 15 days at no cost, so you can see its true baseline. [Request Measurement]
Velocity, Acceleration, Displacement, and Demodulation: Which Serves What Purpose?
These four parameters are not in competition; they cover different frequency ranges.
Parameter | What It Represents | Useful Frequency Range | What It Is Used For |
Displacement (µm) | Amplitude of movement | Low frequency | Fluid-film journal bearings, gross unbalance. Rarely used in general condition monitoring |
Velocity (mm/s) | Speed of movement | Mid frequency | The preferred metric for general monitoring. Unbalance, misalignment, looseness, bent shaft. Unit used by ISO 20816 |
Acceleration (g) | Force of impact | High frequency | Early bearing defects, gear meshing faults, pump cavitation, and turbulence |
Envelope / Demodulation | Repetition rate of impacts | High-pass filter + demodulation | Very early detection of localized bearing defects |
Enveloping deserves special attention because it is the technique that provides the earliest detection while being the least understood. When a rolling element strikes a defect on a raceway, the bearing "rings like a bell" at its natural frequency. Demodulation filters out the ringing sound—the high frequency—and isolates the rate at which impacts occur. This brings out peak frequencies that would otherwise remain buried in the noise floor of a conventional spectrum. It is particularly valuable for pumps and blowers, where flow noise closely resembles the signature of a severely worn bearing.
How to Read a Spectrum Without Being a Certified Analyst
All diagnostic analysis relies on a single principle: every fault impacts the machine at a characteristic frequency, and that frequency is expressed as a multiple of running speed (1X = once per revolution). Armed with this, a manager can read a spectrum well enough to ask the right questions.
Unbalance
Signature: A single dominant peak at 1X, without significant harmonics (unless unbalance is severe). Radial vibration with similar amplitude in all radial directions.
Phase: Approximately 90° phase shift between horizontal and vertical positions.
Note: Amplitude increases with rotational speed—squared—so an unbalance level that is tolerable at 900 rpm can become destructive at 3,600 rpm.
Typical Causes: Buildup or erosion on fan impellers and rotors, loss of balance weights, or product accumulation.
Misalignment
Signature: High peak at 2X. In severe cases, harmonics extend up to 10X.
Distinguishing Feature: Misalignment generates high AXIAL vibration, whereas unbalance does not.
Phase: 180° phase shift across the coupling—axial for angular misalignment, radial for parallel (offset) misalignment.
Severity Rule of Thumb (useful for meetings):
2X / 1X Ratio | Interpretation |
2X below 50% of 1X | Acceptable |
2X between 50% and 150% of 1X | Likely coupling damage |
2X above 150% of 1X | Severe misalignment: immediate repair required |
A myth worth busting: Misalignment does not waste a measurable amount of energy. The U.S. Department of Energy, in its technical sheet on shaft alignment, explicitly states that misalignment has no measurable effect on motor efficiency. What it does do is destroy bearings, seals, and shafts while generating excessive radial and axial vibration. That is the correct argument, and it is more than sufficient.
The same DOE document publishes official alignment tolerances: between 0.3 and 3.0 mils of parallel offset and between 0.3 and 2.0 mils per inch of angular misalignment, depending on motor speed (900 to 3,600 rpm). The higher the speed, the tighter the tolerance. If your facility aligns 3,600 rpm motors using "straightedges and visual checks," your equipment is out of tolerance by definition.
Mechanical Looseness
Signature: A long train of running speed harmonics—2X, 3X, 4X, 5X, 6X…—or half-order harmonics (0.5X, 1.5X, 2.5X…), showing abnormally high amplitudes and a messy spectrum appearance.
Practical Threshold: Three or more multiples of running speed with amplitudes exceeding 20% of the 1X peak.
Sub-types: Looseness between bearing and shaft tends to display a dominant peak at 3X; looseness between bearing outer ring and housing often shows peaks at 1X and 4X.
Bearing Defect
A bearing has four characteristic defect frequencies, which depend on the number of rolling elements, ball diameter, pitch diameter, and contact angle:
Abbreviation | Name | Spectrum Signature |
BPFO | Ball Pass Frequency Outer Race | Harmonics of BPFO, typically 8 to 10, without sidebands |
BPFI | Ball Pass Frequency Inner Race | BPFI harmonics with sidebands spaced at 1X (as defect enters/leaves load zone) |
BSF | Ball Spin Frequency | Harmonics of BSF, with sidebands spaced at FTF |
FTF | Fundamental Train Frequency (Cage) | Rarely appears alone; modulates race frequencies, generating sum & difference frequencies |
The non-expert reading trick: None of these frequencies are exact integer multiples of running speed. They are non-synchronous. If peaks appear in the spectrum that do not fall on exact multiples of 1X, suspect bearing issues—and request an enveloping analysis.
Electrical Problems
Master Indicator: A peak at twice the line frequency (2X line frequency). In Colombia (and US, operating at 60 Hz), that corresponds to 120 Hz = 7,200 CPM.
Stator Issues: High peak at 2X line frequency (eccentricity, shorted laminations, loose iron).
Rotor Issues: Pole pass frequency sidebands surrounding the 1X peak and its harmonics (broken/cracked rotor bars).
RBPF (Rotor Bar Pass Frequency): Number of bars × rpm, appearing at high frequency, often with sidebands at 2X line frequency.
The ultimate free field test: Cut the power and watch the spectrum. If the peak vanishes instantly, the origin is electrical. If it decays gradually as the machine coasts down, it is mechanical. This simple test resolves more disputes between maintenance and electrical teams than any written report.
Want the spectral signature poster for your maintenance shop?
We'll send you our diagnostic matrix in PDF format—covering unbalance, misalignment, looseness, bearing faults, and electrical issues—ready to print. [Request the Chart]
Five Questions to Ask the Person Measuring Your Machinery
Even without being an analyst, these five questions will immediately separate a high-quality service provider from a generic report filler:
Under which group and support type did you classify each machine? If they don't know, they aren't applying ISO 20816.
Are you citing ISO 20816-3:2022 or the withdrawn ISO 10816-3?
What is the trend over time, rather than just the single point reading? An isolated measurement is not condition monitoring.
Did you measure acceleration and enveloping, or only overall velocity? Measuring only velocity means bearing faults won't be visible until it is too late.
Does your conclusion identify a specific failure mode, or does it simply say "inspect"? A proper diagnosis should be verifiable once the machine is opened up.
Why Periodic Measurements Fall Short
Quarterly measurements using handheld devices suffer from a structural flaw: the measurement interval is significantly longer than the P-F interval of most bearing failures, which typically spans 2 to 10 weeks. If you measure every 90 days, you will at best detect the fault when it is already advanced; at worst, the machine fails between two visits after the previous report indicated "acceptable condition."
Continuous monitoring doesn't change the underlying physics or standards: it changes the temporal resolution. High time-resolution reveals what no quarterly route can ever capture—the exact moment vibration shifted, and what the machine was doing on that specific day (which product, what speed, which operator, or which shift). That operational context is what turns a raw data point into an actionable root cause.
The governing framework for establishing such a program is ISO 17359:2018, which outlines general guidelines for machine condition monitoring systems, along with ISO 13373-1 for vibration measurement procedures—covering transducer selection, location, mounting, and continuous vs. periodic monitoring. For electric motors specifically, ISO 13373-9 details diagnostic techniques tailored for motors above 15 kW.
Conclusion
You don't need to be certified in vibration analysis to effectively manage a predictive maintenance program. You only need three things: knowing that ISO 20816 measures severity rather than diagnosis; understanding that trends matter more than single numbers; and being able to spot the five fundamental signatures—1X for unbalance, 2X plus axial for misalignment, harmonics train for looseness, non-synchronous peaks for bearing faults, and 120 Hz for electrical faults.
With these tools, you stop signing off on shutdown decisions based solely on someone else's word, and start asking the questions that ensure your measurement service is worth every penny.
Want to view your machines' spectra on a live dashboard without waiting for quarterly reports?
Schedule a 30-minute demo featuring real data from an operational plant. [Schedule Demo]
References and Sources
ISO 20816-3:2022 — Mechanical vibration: Measurement and evaluation of machine vibration, Part 3
ISO 10816-3:2009 — estado Withdrawn en el catálogo oficial de ISO
SKF — Spectrum Analysis: The Key Features of Analyzing Spectra (Jason Mais, SKF USA, PDF)
Fluke — How Demodulation Helps You Detect Bearing Faults Early
Power-MI — Typical bearing defects and spectral identification
ISO 13373-1:2002 — Vibration condition monitoring, Part 1: General procedures
ISO 17359:2018 — Condition monitoring and diagnostics of machines: General guidelines
Article prepared for Smartic — Industry 4.0, Industrial IoT, and Predictive Maintenance. Want to see Smartic in action at your plant? Schedule a 30-minute demo.




Comments